NF ISO 13612-2
Heating and cooling systems in buildings - Method for calculation of the system performance and system design for heat pump systems - Part 2 : energy calculation
ISO 13612 is applicable to heat pumps for space heating and cooling, heat pump water heaters (HPWH), and heat pumps with combined space heating and/or cooling and domestic hot water production, in alternate or simultaneous operation, where the same heat pump is used for space heating and domestic hot water heating. ISO 13612-2:2014 provides a calculation method under steady conditions that corresponds to one calculation step. The results of this calculation are incorporated in larger building models and take into account the influence of the external conditions and building control that influence the energy requirements for heating and cooling supplied by the heat pump system. ISO 13612-2:2014 specifies the required inputs, calculation methods, and required outputs for output thermal power generation for space heating and cooling and domestic hot water production of the following heat pump systems, including control: electrically driven vapour compression cycle (VCC) heat pumps; combustion engine-driven vapour compression cycle heat pumps; thermally driven vapour absorption cycle (VAC) heat pumps; using combinations of heat source and heat distribution.
ISO 13612 is applicable to heat pumps for space heating and cooling, heat pump water heaters (HPWH), and heat pumps with combined space heating and/or cooling and domestic hot water production, in alternate or simultaneous operation, where the same heat pump is used for space heating and domestic hot water heating.
ISO 13612-2:2014 provides a calculation method under steady conditions that corresponds to one calculation step.
The results of this calculation are incorporated in larger building models and take into account the influence of the external conditions and building control that influence the energy requirements for heating and cooling supplied by the heat pump system.
ISO 13612-2:2014 specifies the required inputs, calculation methods, and required outputs for output thermal power generation for space heating and cooling and domestic hot water production of the following heat pump systems, including control: electrically driven vapour compression cycle (VCC) heat pumps; combustion engine-driven vapour compression cycle heat pumps; thermally driven vapour absorption cycle (VAC) heat pumps; using combinations of heat source and heat distribution.
- Avant-proposiv
- Introductionv
-
1 Domaine d'application1
-
2 Références normatives2
-
3 Termes et définitions2
-
4 Symboles et termes abrégés7
-
5 Principe de la méthode9
-
6 Calcul du sous-système de génération21
- Annexe A (informative) Construction de la matrice de COP avec un seul résultat d'essai46
- Annexe B (informative) Calcul du COP basé sur l'interpolation de valeurs57
- Annexe C (informative) Calcul du COP et des puissances thermiques de la pompe à chaleur dans des conditions de charge partielle63
- Annexe D (informative) Modèle de pompe à chaleur dans le programme BEST70
- Annexe E (informative) Évaluation énergétique d'autres types de pompes à chaleur ("systèmes de chauffage de l'eau par pompe à chaleur au CO2" et "systèmes combinés climatiseur/chauffe-eau")105
- Bibliographie123
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ