NF EN ISO 25745-1

NF EN ISO 25745-1

November 2012
Standard Cancelled

Energy performance of lifts, escalators and moving walks - Part 1 : energy measurement and verification

ISO 25745-1:2012 specifies: a) methods of measuring actual energy consumption of lifts, escalators and moving walks on a single unit basis; b) methods of carrying out periodic energy verification checks on lifts, escalators and moving walks in operation. ISO 25745-1:2012 only considers the energy performance during the operational portion of the life cycle of the lifts, escalators or moving walks.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

November 2012

Number of pages

26 p.

Reference

NF EN ISO 25745-1

ICS Codes

91.140.90   Lifts. Escalators

Classification index

P82-270-1

Print number

1 - 08/11/2012

International kinship

European kinship

EN ISO 25745-1:2012
Sumary
Energy performance of lifts, escalators and moving walks - Part 1 : energy measurement and verification

ISO 25745-1:2012 specifies: a) methods of measuring actual energy consumption of lifts, escalators and moving walks on a single unit basis; b) methods of carrying out periodic energy verification checks on lifts, escalators and moving walks in operation.

ISO 25745-1:2012 only considers the energy performance during the operational portion of the life cycle of the lifts, escalators or moving walks.

Standard replaced by (1)
NF EN ISO 25745-1
July 2023
Standard Current
Energy performance of lifts, escalators and moving walks - Part 1 : energy measurement and verification

<p class="MsoBodyText"><span lang="EN-GB">This document specifies:</span></p> <p class="ListNumber1" style="mso-list: l2 level1 lfo4;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">a)<span style="font: 7.0pt 'Times New Roman';">       </span></span></span><!--[endif]--><span lang="EN-GB">methods of measuring actual energy consumption of lifts, escalators and moving walks on a single unit basis;</span></p> <p class="ListNumber1" style="mso-list: l2 level1 lfo4;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">b)<span style="font: 7.0pt 'Times New Roman';">       </span></span></span><!--[endif]--><span lang="EN-GB">methods of carrying out periodic energy verification checks on lifts, escalators and moving walks in operation.</span></p> <p class="MsoBodyText"><span lang="EN-GB">This document only considers the energy performance during the operational portion of the life cycle of the lifts, escalators or moving walks.</span></p> <p class="MsoBodyText"><span lang="EN-GB">For lifts, this document does not cover energy aspects, such as:</span></p> <p class="ListNumber1" style="mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">a)<span style="font: 7.0pt 'Times New Roman';">       </span></span></span><!--[endif]--><span lang="EN-GB">hoistway lighting;</span></p> <p class="ListNumber1" style="mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">b)<span style="font: 7.0pt 'Times New Roman';">       </span></span></span><!--[endif]--><span lang="EN-GB">heating and cooling equipment, including fans in the lift car;</span></p> <p class="ListNumber1" style="mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">c)<span style="font: 7.0pt 'Times New Roman';">        </span></span></span><!--[endif]--><span lang="EN-GB">machine room lighting;</span></p> <p class="ListNumber1" style="mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">d)<span style="font: 7.0pt 'Times New Roman';">       </span></span></span><!--[endif]--><span lang="EN-GB">machine room heating, ventilation and air conditioning;</span></p> <p class="ListNumber1" style="mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">e)<span style="font: 7.0pt 'Times New Roman';">       </span></span></span><!--[endif]--><span lang="EN-GB">non-lift, display systems, closed circuit television security cameras, etc.;</span></p> <p class="ListNumber1" style="mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">f)<span style="font: 7.0pt 'Times New Roman';">         </span></span></span><!--[endif]--><span lang="EN-GB">non-lift, monitoring systems (building management systems, etc.);</span></p> <p class="ListNumber1" style="mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">g)<span style="font: 7.0pt 'Times New Roman';">       </span></span></span><!--[endif]--><span lang="EN-GB">the effect of lift group dispatching on energy consumption;</span></p> <p class="ListNumber1" style="mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">h)<span style="font: 7.0pt 'Times New Roman';">       </span></span></span><!--[endif]--><span lang="EN-GB">non-lift equipment consumption through the power sockets;</span></p> <p class="ListNumber1" style="mso-list: l0 level1 lfo3;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">i)<span style="font: 7.0pt 'Times New Roman';">         </span></span></span><!--[endif]--><span lang="EN-GB">energy storage systems if used as an alternative energy source for operation.</span></p> <p class="MsoBodyText"><span lang="EN-GB">For escalators and moving walks, this document does not cover energy aspects of the ancillary equipment, such as:</span></p> <p class="ListNumber1" style="mso-list: l3 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">a)<span style="font: 7.0pt 'Times New Roman';">       </span></span></span><!--[endif]--><span lang="EN-GB">lighting with the exception of comb plate lighting and step gap lighting and traffic light;</span></p> <p class="ListNumber1" style="mso-list: l3 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">b)<span style="font: 7.0pt 'Times New Roman';">       </span></span></span><!--[endif]--><span lang="EN-GB">cooling and heating;</span></p> <p class="ListNumber1" style="mso-list: l3 level1 lfo2;"><!-- [if !supportLists]--><span lang="EN-GB" style="mso-fareast-font-family: Cambria; mso-bidi-font-family: Cambria;"><span style="mso-list: Ignore;">c)<span style="font: 7.0pt 'Times New Roman';">        </span></span></span><!--[endif]--><span lang="EN-GB">alarm devices and emergency battery supplies equipment, etc.</span></p>

Table of contents
View the extract
  • Avant-propos
    iv
  • Introduction
    v
  • 1 Domaine d'application
    1
  • 1.1 Généralités
    1
  • 1.2 Ascenseurs
    1
  • 1.3 Escaliers mécaniques et trottoirs roulants
    1
  • 2 Termes et définitions
    2
  • 3 Mesurage et vérification de la consommation énergétique des ascenseurs, escaliers mécaniques et trottoirs roulants
    4
  • 3.1 Généralités
    4
  • 3.2 Mesurages de l'énergie consommée par les ascenseurs et mesurages de la puissance consommée par les escaliers mécaniques et les trottoirs roulants
    5
  • 3.3 Contrôle de conformité énergétique des ascenseurs, escaliers mécaniques et trottoirs roulants
    5
  • 3.4 Installations comportant plusieurs ascenseurs, escaliers mécaniques ou trottoirs roulants
    5
  • 4 Modes opératoires de mesurage pour une installation d'ascenseur
    5
  • 4.1 Préambule
    5
  • 4.2 Modes opératoires pour les mesurages de l'énergie
    6
  • 4.3 Modes opératoires pour le contrôle de conformité énergétique
    8
  • 5 Modes opératoires de mesurage pour une installation d'escalier mécanique ou de trottoir roulant
    9
  • 5.1 Préambule
    9
  • 5.2 Modes opératoires pour les mesurages de la puissance
    10
  • 5.3 Modes opératoires pour le contrôle de conformité de la puissance
    11
  • 6 Compte-rendu
    11
  • 6.1 Informations générales
    11
  • 6.2 Compte-rendu relatif à un ascenseur
    11
  • 6.3 Contrôle de conformité de la consommation énergétique d'un ascenseur
    12
  • 6.4 Compte-rendu énergétique d'un escalier mécanique ou d'un trottoir roulant
    12
  • 6.5 Compte-rendu du contrôle de conformité énergétique d'un escalier mécanique ou d'un trottoir roulant
    13
  • Annexe A (informative) Points de raccordement des instruments de mesure
    14
  • Bibliographie
    16
ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ