NF EN ISO 16852

NF EN ISO 16852

January 2017
Standard Current

Flame arresters - Performance requirements, test methods and limits for use

ISO 16852:2016 specifies the requirements for flame arresters that prevent flame transmission when explosive gas-air or vapour-air mixtures are present. It establishes uniform principles for the classification, basic construction and information for use, including the marking of flame arresters, and specifies test methods to verify the safety requirements and determine safe limits of use. This International Standard is valid for pressures ranging from 80 kPa to 160 kPa and temperatures ranging from −20 °C to + 150 °C. NOTE 1 For flame arresters with operational conditions inside the scope, but outside atmospheric conditions, see 7.4. NOTE 2 In designing and testing flame arresters for operation under conditions other than those specified above, this International Standard can be used as a guide. However, additional testing related specifically to the intended conditions of use is advisable. This is particularly important when high temperatures and pressures are applied. The test mixtures might need to be modified in these cases. NOTE 3 An additional standard IMO MSC/Circ. 677 for maritime application from IMO (International Maritime Organization) exists. ISO 16852:2016 is not applicable to the following: - external safety-related measurement and control equipment that might be required to keep the operational conditions within the established safe limits; NOTE 4 Integrated measurement and control equipment, such as integrated temperature and flame sensors as well as parts which, for example, intentionally melt (retaining pin), burn away (weather hoods) or bend (bimetallic strips), is within the scope of this International Standard. - flame arresters used for explosive mixtures of vapours and gases, which tend to self-decompose (e.g. acetylene) or which are chemically unstable; - flame arresters used for carbon disulphide, due to its special properties; - flame arresters whose intended use is for mixtures other than gas-air or vapour-air mixtures (e.g. higher oxygen-nitrogen ratio, chlorine as oxidant, etc.); - flame arrester test procedures for internal-combustion compression ignition engines; - fast acting valves, extinguishing systems and other explosion isolating systems.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

January 2017

Number of pages

62 p.

Reference

NF EN ISO 16852

ICS Codes

13.220.10   Fire-fighting

Classification index

S66-402

Print number

1

International kinship

European kinship

EN ISO 16852:2016
Sumary
Flame arresters - Performance requirements, test methods and limits for use

ISO 16852:2016 specifies the requirements for flame arresters that prevent flame transmission when explosive gas-air or vapour-air mixtures are present. It establishes uniform principles for the classification, basic construction and information for use, including the marking of flame arresters, and specifies test methods to verify the safety requirements and determine safe limits of use.

This International Standard is valid for pressures ranging from 80 kPa to 160 kPa and temperatures ranging from −20 °C to + 150 °C.

NOTE 1 For flame arresters with operational conditions inside the scope, but outside atmospheric conditions, see 7.4.

NOTE 2 In designing and testing flame arresters for operation under conditions other than those specified above, this International Standard can be used as a guide. However, additional testing related specifically to the intended conditions of use is advisable. This is particularly important when high temperatures and pressures are applied. The test mixtures might need to be modified in these cases.

NOTE 3 An additional standard IMO MSC/Circ. 677 for maritime application from IMO (International Maritime Organization) exists.

ISO 16852:2016 is not applicable to the following:

- external safety-related measurement and control equipment that might be required to keep the operational conditions within the established safe limits;

NOTE 4 Integrated measurement and control equipment, such as integrated temperature and flame sensors as well as parts which, for example, intentionally melt (retaining pin), burn away (weather hoods) or bend (bimetallic strips), is within the scope of this International Standard.

- flame arresters used for explosive mixtures of vapours and gases, which tend to self-decompose (e.g. acetylene) or which are chemically unstable;

- flame arresters used for carbon disulphide, due to its special properties;

- flame arresters whose intended use is for mixtures other than gas-air or vapour-air mixtures (e.g. higher oxygen-nitrogen ratio, chlorine as oxidant, etc.);

- flame arrester test procedures for internal-combustion compression ignition engines;

- fast acting valves, extinguishing systems and other explosion isolating systems.

Replaced standards (1)
NF EN ISO 16852
June 2011
Standard Cancelled
Flame arresters - Performance requirements, test methods and limits for use

Le présent document spécifie les exigences applicables aux arrête-flammes qui préviennent la transmission d'une flamme en présence de mélanges explosifs gaz-air ou vapeur-air. Il établit des principes homogènes pour la classification, la construction de base et les informations pour l'utilisation, y compris le marquage des arrête-flammes et spécifie des méthodes d'essai permettant de vérifier les exigences de sécurité et de déterminer des limites de sécurité d'utilisation.

Table of contents
View the extract
  • 1 Domaine d'application
  • 2 Références normatives
  • 3 Termes et définitions
  • 4 Abréviation et symboles
  • 5 Phénomènes dangereux et classification des arrête-flammes
  • 6 Exigences générales
  • 7 Exigences spécifiques applicables aux arrête-flammes statiques
  • 8 Exigences spécifiques applicables aux arrête-flammes antidétonation à produit liquide
  • 9 Exigences spécifiques applicables aux arrête-flammes dynamiques (soupapes d'évent à grande vitesse)
  • 10 Exigences spécifiques applicables aux arrête-flammes hydrauliques
  • 11 Essai des arrête-flammes installés sur ou dans un équipement convoyant des gaz
  • 12 Informations pour l'utilisation
  • Annexe A Mesurage du débit
  • Annexe B Informations pour sélectionner les arrête-flammes
  • Annexe C Bonnes pratiques
  • Bibliographie
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ